Results 1 - 20 de 56
Filter
1.
Korean Journal of Radiology ; : 983-995, 2023.
Article in English | WPRIM | ID: wpr-1002426

ABSTRACT

Objective@#To compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA). @*Materials and Methods@#This retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020.Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ). @*Results@#No significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all).The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754–0.841] vs. 0.753 [0.697–0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884). @*Conclusion@#CECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.

2.
Ultrasonography ; : 265-274, 2023.
Article in English | WPRIM | ID: wpr-969229

ABSTRACT

Purpose@#This study compared two different two-dimensional shear wave elastography techniques—plane wave imaging (PWI) and multi-beam (MB) imaging—from the same vendor to evaluate liver fibrosis. @*Methods@#In this prospective study, 42 patients with chronic liver disease who had recently undergone magnetic resonance elastography (<3 months) were enrolled, and their liver stiffness (LS) values were measured using PWI or MB. The LS values (kPa) were compared using the Wilcoxon rank-sum test. Inter-technique reproducibility and intra-observer repeatability were assessed using Bland-Altman analysis with 95% limits of agreement (LOA) and coefficients of variation (CVs). The cutoff values for predicting severe fibrosis (≥F3) were estimated using receiver operating characteristic curve (ROC) analysis, with magnetic resonance elastography as the reference standard. @*Results@#PWI exhibited technical failure in four patients. Therefore, 38 patients underwent both examinations. The LS values showed moderate agreement between PWI and MB (CV, 22.5%) and 95% LOA of -3.71 to 7.44 kPa. The MB technique showed good intra-observer agreement (CV, 8.1%), while PWI showed moderate agreement (CV, 11.0%). The cutoff values of PWI and MB for diagnosing ≥F3 were 12.3 kPa and 13.8 kPa, respectively, with areas under the ROC curve of 0.89 and 0.95 (sensitivity, 100% and 100%; specificity, 65.6% and 85.7%). @*Conclusion@#The LS values significantly differed between PWI and MB, hindering their interchangeable use in longitudinal follow-up. Considering its low technical failure rate and better repeatability, the MB technique may be preferable for evaluating liver fibrosis in chronic liver disease patients.

3.
Korean Journal of Radiology ; : 86-94, 2023.
Article in English | WPRIM | ID: wpr-968263

ABSTRACT

Objective@#To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo. @*Materials and Methods@#Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60°C in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination. @*Results@#In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm3 vs. 12.5 ± 2.14 cm3 , p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group (p < 0.001 for all). @*Conclusion@#RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.

4.
Clinical and Molecular Hepatology ; : 362-379, 2022.
Article in English | WPRIM | ID: wpr-937343

ABSTRACT

Hepatocellular carcinoma (HCC) is a unique cancer entity that can be noninvasively diagnosed using imaging modalities without pathologic confirmation. In 2018, several major guidelines for HCC were updated to include hepatobiliary contrast agent magnetic resonance imaging (HBA-MRI) and contrast-enhanced ultrasound (CEUS) as major imaging modalities for HCC diagnosis. HBA-MRI enables the achievement of high sensitivity in HCC detection using the hepatobiliary phase (HBP). CEUS is another imaging modality with real-time imaging capability, and it is reported to be useful as a second-line modality to increase sensitivity without losing specificity for HCC diagnosis. However, until now, there is an unsolved discrepancy among guidelines on whether to accept “HBP hypointensity” as a definite diagnostic criterion for HCC or include CEUS in the diagnostic algorithm for HCC diagnosis. Furthermore, there is variability in terminology and inconsistencies in the definition of imaging findings among guidelines; therefore, there is an unmet need for the development of a standardized lexicon. In this article, we review the performance and limitations of HBA-MRI and CEUS after guideline updates in 2018 and briefly introduce some future aspects of imaging-based HCC diagnosis.

5.
Korean Journal of Radiology ; : 180-188, 2022.
Article in English | WPRIM | ID: wpr-918226

ABSTRACT

Objective@#To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. @*Materials and Methods@#This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0–F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal–Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. @*Results@#Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97–0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0–F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97–0.98 (sensitivity 91.2%–95.9%, specificity 90.7%–99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0–F3 stages. @*Conclusion@#The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

6.
Korean Journal of Radiology ; : 714-724, 2021.
Article in English | WPRIM | ID: wpr-902470

ABSTRACT

Objective@#To evaluate the value of 18 F-fluorodeoxyglucose PET/MRI added to contrast-enhanced CT (CECT) in initial staging, assessment of resectability, and postoperative follow-up of biliary tract cancer. @*Materials and Methods@#This retrospective study included 100 patients (initial workup [n = 65] and postoperative follow-up [n = 35]) who had undergone PET/MRI and CECT for bile duct or gallbladder lesions between January 2013 and March 2020.Two radiologists independently reviewed the CECT imaging set and CECT plus PET/MRI set to determine the likelihood of malignancy, local and overall resectability, and distant metastasis in the initial workup group, and local recurrence and distant metastasis in the follow-up group. Diagnostic performances of the two imaging sets were compared using clinical-surgicalpathologic findings as standards of reference. @*Results@#The diagnostic performance of CECT significantly improved after the addition of PET/MRI for liver metastasis (area under the receiver operating characteristic curve [A z]: 0.77 vs. 0.91 [p = 0.027] for reviewer 1; 0.76 vs. 0.92 [p = 0.021] for reviewer 2), lymph node metastasis (0.73 vs. 0.92 [p = 0.004]; 0.81 vs. 0.92 [p = 0.023]), and overall resectability (0.79 vs.0.92 [p = 0.007]; 0.82 vs. 0.94 [p = 0.021]) in the initial workup group. In the follow-up group, the diagnostic performance of CECT plus PET/MRI was significantly higher than that of CECT imaging for local recurrence (0.81 vs. 1.00 [p = 0.029]; 0.82 vs. 0.94 [p = 0.045]). @*Conclusion@#PET/MRI may add value to CECT in patients with biliary tract cancer both in the initial workup for staging and determination of overall resectability and in follow-up for local recurrence.

7.
Korean Journal of Radiology ; : 1066-1076, 2021.
Article in English | WPRIM | ID: wpr-902449

ABSTRACT

Objective@#To evaluate the performance of the 2018 Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) Practice Guidelines (hereafter, PG) for the diagnosis of hepatocellular carcinoma (HCC) using gadoxetic acid-enhanced MRI, compared to the Liver Imaging-Reporting and Data System (LI-RADS) version 2018 (hereafter, v2018). @*Materials and Methods@#From January 2013 to October 2015, treatment-naïve hepatic lesions (≥ 1 cm) on gadoxetic acidenhanced MRI in consecutive patients with chronic hepatitis B or cirrhosis were retrospectively evaluated. For each lesion, three radiologists independently analyzed the imaging features and classified the lesions into categories according to the 2018 KLCA-NCC PG and LI-RADS v2018. The imaging features and categories were determined by consensus. Generalized estimating equation (GEE) models were used to compare the per-lesion diagnostic performance of the 2018 KLCA-NCC PG and LI-RADS v2018 using the consensus data. @*Results@#In total, 422 lesions (234 HCCs, 45 non-HCC malignancies, and 143 benign lesions) from 387 patients (79% male; mean age, 59 years) were included. In all lesions, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity and lower specificity than LR-5 (LI-RADS v2018) (87.2% [204/234] vs. 80.8% [189/234], p < 0.001; 86.2% [162/188] vs. 91.0% [171/188], p = 0.002). However, in lesions of size ≥ 2 cm, the definite HCC had a higher sensitivity than the LR-5 (86.8% [164/189] vs. 82.0 (155/189), p = 0.002) without a reduction in the specificity (80.0% [48/60] vs. 83.3% [50/60], p = 0.15).In all lesions, the sensitivity and specificity of the definite/probable HCC (2018 KLCA-NCC PG) and LR-5/4 did not differ significantly (89.7% [210/234] vs. 91.5% [214/234], p = 0.204; 83.5% [157/188] vs. 79.3% [149/188], p = 0.071). @*Conclusion@#For the diagnosis of HCC of size ≥ 2 cm, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity than LR-5, without a reduction in specificity. The definite/probable HCC (2018 KLCA-NCC PG) had a similar sensitivity and specificity to that those of the LR-5/4.

8.
Korean Journal of Radiology ; : 714-724, 2021.
Article in English | WPRIM | ID: wpr-894766

ABSTRACT

Objective@#To evaluate the value of 18 F-fluorodeoxyglucose PET/MRI added to contrast-enhanced CT (CECT) in initial staging, assessment of resectability, and postoperative follow-up of biliary tract cancer. @*Materials and Methods@#This retrospective study included 100 patients (initial workup [n = 65] and postoperative follow-up [n = 35]) who had undergone PET/MRI and CECT for bile duct or gallbladder lesions between January 2013 and March 2020.Two radiologists independently reviewed the CECT imaging set and CECT plus PET/MRI set to determine the likelihood of malignancy, local and overall resectability, and distant metastasis in the initial workup group, and local recurrence and distant metastasis in the follow-up group. Diagnostic performances of the two imaging sets were compared using clinical-surgicalpathologic findings as standards of reference. @*Results@#The diagnostic performance of CECT significantly improved after the addition of PET/MRI for liver metastasis (area under the receiver operating characteristic curve [A z]: 0.77 vs. 0.91 [p = 0.027] for reviewer 1; 0.76 vs. 0.92 [p = 0.021] for reviewer 2), lymph node metastasis (0.73 vs. 0.92 [p = 0.004]; 0.81 vs. 0.92 [p = 0.023]), and overall resectability (0.79 vs.0.92 [p = 0.007]; 0.82 vs. 0.94 [p = 0.021]) in the initial workup group. In the follow-up group, the diagnostic performance of CECT plus PET/MRI was significantly higher than that of CECT imaging for local recurrence (0.81 vs. 1.00 [p = 0.029]; 0.82 vs. 0.94 [p = 0.045]). @*Conclusion@#PET/MRI may add value to CECT in patients with biliary tract cancer both in the initial workup for staging and determination of overall resectability and in follow-up for local recurrence.

9.
Korean Journal of Radiology ; : 1066-1076, 2021.
Article in English | WPRIM | ID: wpr-894745

ABSTRACT

Objective@#To evaluate the performance of the 2018 Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) Practice Guidelines (hereafter, PG) for the diagnosis of hepatocellular carcinoma (HCC) using gadoxetic acid-enhanced MRI, compared to the Liver Imaging-Reporting and Data System (LI-RADS) version 2018 (hereafter, v2018). @*Materials and Methods@#From January 2013 to October 2015, treatment-naïve hepatic lesions (≥ 1 cm) on gadoxetic acidenhanced MRI in consecutive patients with chronic hepatitis B or cirrhosis were retrospectively evaluated. For each lesion, three radiologists independently analyzed the imaging features and classified the lesions into categories according to the 2018 KLCA-NCC PG and LI-RADS v2018. The imaging features and categories were determined by consensus. Generalized estimating equation (GEE) models were used to compare the per-lesion diagnostic performance of the 2018 KLCA-NCC PG and LI-RADS v2018 using the consensus data. @*Results@#In total, 422 lesions (234 HCCs, 45 non-HCC malignancies, and 143 benign lesions) from 387 patients (79% male; mean age, 59 years) were included. In all lesions, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity and lower specificity than LR-5 (LI-RADS v2018) (87.2% [204/234] vs. 80.8% [189/234], p < 0.001; 86.2% [162/188] vs. 91.0% [171/188], p = 0.002). However, in lesions of size ≥ 2 cm, the definite HCC had a higher sensitivity than the LR-5 (86.8% [164/189] vs. 82.0 (155/189), p = 0.002) without a reduction in the specificity (80.0% [48/60] vs. 83.3% [50/60], p = 0.15).In all lesions, the sensitivity and specificity of the definite/probable HCC (2018 KLCA-NCC PG) and LR-5/4 did not differ significantly (89.7% [210/234] vs. 91.5% [214/234], p = 0.204; 83.5% [157/188] vs. 79.3% [149/188], p = 0.071). @*Conclusion@#For the diagnosis of HCC of size ≥ 2 cm, the definite HCC (2018 KLCA-NCC PG) had a higher sensitivity than LR-5, without a reduction in specificity. The definite/probable HCC (2018 KLCA-NCC PG) had a similar sensitivity and specificity to that those of the LR-5/4.

10.
Korean Journal of Radiology ; : 354-365, 2021.
Article in English | WPRIM | ID: wpr-875286

ABSTRACT

Objective@#To investigate the diagnostic performance of contrast-enhanced ultrasound (CEUS) and its role as a second-line imaging modality after gadoxetate-enhanced MRI (Gd-EOB-MRI) in the diagnosis of hepatocellular carcinoma (HCC) among at risk observations. @*Materials and Methods@#We prospectively enrolled participants at risk of HCC with treatment-naïve solid hepatic observations (≥ 1 cm) of Liver Imaging Reporting and Data System (LR)-3/4/5/M during surveillance and performed Gd-EOB-MRI. A total of one hundred and three participants with 103 hepatic observations (mean size, 28.2 ± 24.5 mm; HCCs [n = 79], non-HCC malignancies [n = 15], benign [n = 9]; diagnosed by pathology [n = 57], or noninvasive method [n = 46]) were included in this study. The participants underwent CEUS with sulfur hexafluoride. Arterial phase hyperenhancement (APHE) and washout on Gd-EOB-MRI and CEUS were evaluated. The distinctive washout in CEUS was defined as mild washout 60 seconds after contrast injection. The diagnostic ability of Gd-EOB-MRI and of CEUS as a second-line modality for HCC were determined according to the European Association for the Study of the Liver (EASL) and the Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) guidelines. The diagnostic abilities of both imaging modalities were compared using the McNemar’s test. @*Results@#The sensitivity of CEUS (60.8%) was lower than that of Gd-EOB-MRI (72.2%, p = 0.06 by EASL; 86.1%, p < 0.01 by KLCA-NCC); however, the specificity was 100%. By performing CEUS on the inconclusive observations in Gd-EOB-MRI, HCCs without APHE (n = 10) or washout (n = 12) on Gd-EOB-MRI further presented APHE (80.0%, 8/10) or distinctive washout (66.7%, 8/12) on CEUS, and more HCCs were diagnosed than with Gd-EOB-MRI alone (sensitivity: 72.2% vs. 83.5% by EASL, p < 0.01; 86.1% vs. 91.1% by KCLA-NCC, p = 0.04). There were no false-positive cases for HCC on CEUS. @*Conclusion@#The addition of CEUS to Gd-EOB-MRI as a second-line diagnostic modality increases the frequency of HCC diagnosis without changing the specificities.

11.
Ultrasonography ; : 103-114, 2021.
Article in English | WPRIM | ID: wpr-919512

ABSTRACT

Purpose@#This study quantified the impact of respiratory motion on liver stiffness measurements according to different shear wave elastography (SWE) techniques and region of interest (ROI) methods, using liver fibrosis phantoms. @*Methods@#Three operators measured stiffness values in four phantoms with different stiffness on a moving platform with two SWE techniques (point-SWE [pSWE] and 2-dimensional SWE [2D-SWE]), three types of motion (static mode and moving mode at low and high speeds), and four ROI methods in 2D-SWE (circle, point, box, and multiple). The circular ROI method was used to compare the two SWE techniques. The occurrence of technical failure and unreliable measurements, stiffness values, and measurement time were evaluated. @*Results@#Technical failure was observed only in moving mode for pSWE and 2D-SWE (n=1 for both). Unreliable measurements were also only observed in moving mode and were significantly less common in 2D-SWE (n=1) than in pSWE (n=12) (P<0.001). No statistically significant differences in the technical failure rate or stiffness values were noted between the static and moving modes for both SWE techniques. The technical failure and unreliable measurement rates were not significantly different among the ROI methods for 2D-SWE. Stiffness values did not differ significantly according to the ROI method used in any moving mode. However, the multiple ROI method had significantly shorter measurement times than the circular ROI method for all moving modes. @*Conclusion@#2D-SWE may be preferable for evaluating liver fibrosis in patients with poor breath-hold. Furthermore, 2D-SWE with multiple ROIs enables rapid measurements, without affecting liver stiffness values.

12.
Ultrasonography ; : 217-227, 2021.
Article in English | WPRIM | ID: wpr-919497

ABSTRACT

Purpose@#This study investigated whether the use of ultrasound (US) guidance in transient elastography (TE) improved the technical success and reliability of liver stiffness (LS) measurements and whether 2-dimensional (2D) shear wave elastography (SWE) provided reliable LS measurements if TE measurements failed. @*Methods@#In this prospective study, 292 participants (male:female, 189:103; median age, 60 years) with chronic liver disease (CLD) were enrolled. LS was measured via the consecutive use of conventional TE, 2D-SWE, and US-guided TE. The technical success rates and reliable LS measurement rates of the three elastography techniques were compared. The risk factors for TE failure were assessed through univariate and multivariate logistic regression models. @*Results@#US-guided TE was associated with a higher technical success rate (281 of 292, 96.2%) and a higher reliable measurement rate (266 of 292, 91.1%) than conventional TE (technical success: 256 of 292, 87.7%; reliable measurements: 231 of 292, 79.1%; P<0.001 for both). In participants for whom conventional TE failed, 2D-SWE provided high rates of technical success (36 of 36, 100%) and reliable measurements (30 of 36, 83.3%). TE failure was associated with female sex (odds ratio [OR], 5.85; 95% confidence interval [CI], 1.30 to 26.40), severe reverberation artifacts (OR, 8.79; 95% CI, 3.93 to 19.69), and high skin-to-liver capsule depth (OR, 1.23; 95% CI, 1.09 to 1.39). @*Conclusion@#US guidance in TE improved the technical success and reliable measurement rates in the assessment of LS in patients with CLD. In participants for whom TE failed, subsequent 2D-SWE successfully delivered reliable LS measurements.

13.
Korean Journal of Radiology ; : 1974-1984, 2021.
Article in English | WPRIM | ID: wpr-918185

ABSTRACT

Objective@#This study aimed to compare the efficacy between no-touch (NT) radiofrequency ablation (RFA) and conventional RFA using twin internally cooled wet (TICW) electrodes in the bipolar mode for the treatment of small hepatocellular carcinomas (HCC). @*Materials and Methods@#In this single-center, two-arm, parallel-group, prospective randomized controlled study, we performed a 1:1 random allocation of eligible patients with HCCs to receive NT-RFA or conventional RFA between October 2016 and September 2018. The primary endpoint was the cumulative local tumor progression (LTP) rate after RFA. Secondary endpoints included technical conversion rates of NT-RFA, intrahepatic distance recurrence, extrahepatic metastasis, technical parameters, technical efficacy, and rates of complications. Cumulative LTP rates were analyzed using Kaplan-Meier analysis and the Cox proportional hazard regression model. Considering conversion cases from NT-RFA to conventional RFA, intentionto-treat and as-treated analyses were performed. @*Results@#Enrolled patients were randomly assigned to the NT-RFA group (37 patients with 38 HCCs) or the conventional RFA group (36 patients with 38 HCCs). Among the NT-RFA group patients, conversion to conventional RFA occurred in four patients (10.8%, 4/37). According to intention-to-treat analysis, both 1- and 3-year cumulative LTP rates were 5.6%, in the NT-RFA group, and they were 11.8% and 21.3%, respectively, in the conventional RFA group (p = 0.073, log-rank). In the as-treated analysis, LTP rates at 1 year and 3 years were 0% and 0%, respectively, in the NT-RFA group sand 15.6% and 24.5%, respectively, in the conventional RFA group (p = 0.004, log-rank). In as-treated analysis using multivariable Cox regression analysis, RFA type was the only significant predictive factor for LTP (hazard ratio = 0.061 with conventional RFA as the reference, 95% confidence interval = 0.000–0.497; p = 0.004). There were no significant differences in the procedure characteristics between the two groups. No procedure-related deaths or major complications were observed. @*Conclusion@#NT-RFA using TICW electrodes in bipolar mode demonstrated significantly lower cumulative LTP rates than conventional RFA for small HCCs, which warrants a larger study for further confirmation.

14.
Ultrasonography ; : 288-297, 2020.
Article | WPRIM | ID: wpr-835335

ABSTRACT

Purpose@#This study aimed to assess the technical performance of ElastQ Imaging compared with ElastPQ and to investigate the correlation between liver stiffness (LS) values obtained using these two techniques. @*Methods@#This retrospective study included 249 patients who underwent LS measurements using both ElastPQ and ElastQ Imaging equipped on the same machine. The applicability, repeatability (coefficient of variation [CV]), acquisition time, and LS values were compared using the chi-square or Wilcoxon signed-rank tests. In the development group, the correlation between the LS values obtained by the two techniques was assessed with Spearman correlation coefficients and linear regression analysis. In the validation group, the agreement between the estimated and real LS values was evaluated using a Bland-Altman plot. @*Results@#ElastQ Imaging had higher applicability (94.0% vs. 78.3%, P<0.001) and higher repeatability, with a lower median CV (0.127 vs. 0.164, P<0.001) than did ElastPQ. The median acquisition time of ElastQ Imaging was significantly shorter than that of ElastPQ (45.5 seconds vs. 96.5 seconds, P<0.001). The median LS value obtained using ElastQ Imaging was significantly higher than that obtained using ElastPQ (5.60 kPa vs. 5.23 kPa, P<0.001). The LS values between the two techniques exhibited a strong positive correlation (r=0.851, P<0.001) in the development group. The mean difference and 95% limits of agreement were 0.0 kPa (-3.9 to 3.9 kPa) in the validation group. @*Conclusion@#ElastQ Imaging may be more reliable and faster than ElastPQ, with strongly correlated LS measurements.

15.
Ultrasonography ; : 52-59, 2020.
Article | WPRIM | ID: wpr-835327

ABSTRACT

Purpose@#The purpose of this study was to prospectively investigate the intra- and interobserver repeatability of a new 2-dimensional (2D) shear wave elastography (SWE) technique (S-Shearwave Imaging) for assessing liver fibrosis in chronic liver disease patients, and to compare liver stiffness measurements (LSMs) made using 2D-SWE with those made using point SWE (pSWE). @*Methods@#This prospective study received institutional review board approval and informed consent was obtained from all patients. Fifty-three chronic liver disease patients were randomly allocated to group 1 (for intra-observer repeatability [n=33]) or group 2 (for inter-observer repeatability [n=20]). In group 1, two 2D-SWE sessions and one pSWE sessions were performed by one radiologist. In group 2, one 2D-SWE session and one pSWE session were performed by the aforementioned radiologist, and a second 2D-SWE session was performed by another radiologist. The intraclass correlation coefficient (ICC) was used to assess intra- and interobserver reliability. LSMs obtained using 2D-SWE and pSWE were compared and correlated using the paired t test and Pearson correlation coefficient, respectively. @*Results@#LSMs made using 2D-SWE demonstrated excellent intra- and inter-observer repeatability (ICC, 0.997 [95% confidence interval, 0.994 to 0.999]) and 0.995 [0.988 to 0.998], respectively). LSMs made using 2D-SWE were significantly different from those made using pSWE (2.1±0.6 m/sec vs. 1.9±0.6 m/sec, P<0.001), although a significant correlation existed between the 2D-SWE and pSWE LSMs (rho=0.836, P<0.001). @*Conclusion@#S-Shearwave Imaging demonstrated excellent intra- and inter-observer repeatability, and a strong correlation with pSWE measurements of liver stiffness. However, because of the significant difference between LSMs obtained using 2D-SWE and pSWE, these methods should not be used interchangeably.

16.
Ultrasonography ; : 121-129, 2020.
Article | WPRIM | ID: wpr-835314

ABSTRACT

Purpose@#The purpose of this study was to evaluate the intra-observer reproducibility of ultrasound attenuation imaging (ATI) for the noninvasive assessment of hepatic steatosis in patients with suspected hepatic steatosis and the inter-observer reproducibility in asymptomatic volunteers. @*Methods@#This prospective study was approved by our institutional review board and informed consent was obtained from all patients. In group 1, composed of patients with suspected hepatic steatosis (n=143), one abdominal radiologist performed gray-scale ultrasonography and two sessions of ATI. In group 2, composed of healthy volunteers (n=18), three independent sessions of ATI were performed by three abdominal radiologists. The visual degree of hepatic steatosis in all study subjects was graded on a 4-point scale by two independent reviewers using gray-scale ultrasonography. Thereafter, the attenuation coefficient (AC) was correlated with the degree of hepatic steatosis using Spearman rank correlation analysis. Intra-class correlation coefficients (ICCs) were used to assess the intra-observer (group 1) and inter-observer reproducibility (group 2) of ATI measurements. @*Results@#For the intra-observer reproducibility of ATI, the ICC was 0.929 (95% confidence interval [CI], 0.901 to 0.949), and the coefficient of variation was 7.1%. Inter-observer reproducibility of ATI measurements showed an ICC of 0.792 (95% CI, 0.549 to 0.916). The AC showed a significant correlation with the visual grade of hepatic steatosis for both reviewers (rho, 0.780 and 0.695; P<0.001, respectively). @*Conclusion@#ATI showed high intra- and inter-observer reproducibility in the assessment of hepatic steatosis.

17.
Korean Journal of Radiology ; : 1065-1076, 2020.
Article | WPRIM | ID: wpr-833587

ABSTRACT

Objective@#To determine the prognostic value of MRI-based tumor regression grading (mrTRG) in rectal cancer compared withpathological tumor regression grading (pTRG), and to assess the effect of diffusion-weighted imaging (DWI) on interobserveragreement for evaluating mrTRG. @*Materials and Methods@#Between 2007 and 2016, we retrospectively enrolled 321 patients (male:female = 208:113; meanage, 60.2 years) with rectal cancer who underwent both pre-chemoradiotherapy (CRT) and post-CRT MRI. Two radiologistsindependently determined mrTRG using a 5-point grading system with and without DWI in a one-month interval. Two pathologistsgraded pTRG using a 5-point grading system in consensus. Kaplan-Meier estimation and Cox-proportional hazard models wereused for survival analysis. Cohen’s kappa analysis was used to determine interobserver agreement. @*Results@#According to mrTRG on MRI with DWI, there were 6 mrTRG 1, 48 mrTRG 2, 109 mrTRG 3, 152 mrTRG 4, and 6 mrTRG 5.By pTRG, there were 7 pTRG 1, 59 pTRG 2, 180 pTRG 3, 73 pTRG 4, and 2 pTRG 5. A 5-year overall survival (OS) was significantlydifferent according to the 5-point grading mrTRG (p= 0.024) and pTRG (p= 0.038). The 5-year disease-free survival (DFS)was significantly different among the five mrTRG groups (p= 0.039), but not among the five pTRG groups (p= 0.072). OSand DFS were significantly different according to post-CRT MR variables: extramural venous invasion after CRT (hazard ratio= 2.259 for OS, hazard ratio = 5.011 for DFS) and extramesorectal lymph node (hazard ratio = 2.610 for DFS). For mrTRG, kvalue between the two radiologists was 0.309 (fair agreement) without DWI and slightly improved to 0.376 with DWI. @*Conclusion@#mrTRG may predict OS and DFS comparably or even better compared to pTRG. The addition of DWI on T2-weightedMRI may improve interobserver agreement on mrTRG.

18.
Ultrasonography ; : 345-354, 2019.
Article in English | WPRIM | ID: wpr-761991

ABSTRACT

PURPOSE: The purpose of this study was to compare the technical success rate and reliability of measurements made using three shear wave elastography (SWE) techniques and to assess the inter-platform reproducibility of the resultant liver stiffness measurements. METHODS: This prospective study included 54 patients with liver disease. Liver stiffness (LS) measurements were obtained using 2-point SWE techniques (Virtual Touch Quantification and S-Shearwave) and 2-dimensional (2D) SWE, with transient elastography (TE) serving as the reference standard. The technical success rates and measurement reliability of the three techniques were compared. LS values measured using the three SWE techniques and TE were compared using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Intra-class correlation coefficients (ICC) were used to analyze the inter-platform reproducibility of LS measurements. RESULTS: The three SWE techniques and TE showed similar technical success rates (P=0.682) but demonstrated significant differences in the reliability of LS measurements (P=0.006) and mean LS measurements (P<0.001). Despite strong correlations (r=0.73-0.94) between SWE systems, various degrees of inter-platform reproducibility (ICC, 0.58-0.92) were observed for the three SWE techniques. The best agreement was observed between S-Shearwave and TE (ICC, 0.92), and the worst agreement was observed between 2D-SWE and TE (ICC, 0.58). In the Bland-Altman analysis, a tendency toward lower LS values with the three SWE techniques than with TE in patients with F3 and F4 disease was observed. CONCLUSION: Significant inter-system variability was observed in LS measurements made using the three SWE techniques. Therefore, LS values measured using different SWE techniques should not be used interchangeably for longitudinal follow-up.


Subject(s)
Humans , Elasticity Imaging Techniques , Follow-Up Studies , Liver Cirrhosis , Liver Diseases , Liver , Prospective Studies
19.
Ultrasonography ; : 246-254, 2019.
Article in English | WPRIM | ID: wpr-761981

ABSTRACT

PURPOSE: The purpose of this study was to retrospectively compare the technical success and reliability of the measurements made using two 2-dimensional (2D) shear wave elastography (SWE) systems using the comb-push technique from the same manufacturer and to assess the intersystem reproducibility of the resultant liver stiffness (LS) measurements. METHODS: Ninety-four patients with suspected chronic liver diseases were included in this retrospective study. LS measurements were obtained using two 2D-SWE systems (LOGIQ E9 and LOGIQ S8) from the same manufacturer, with transient elastography (TE) serving as the reference standard, on the same day. The technical success rates and reliability of the measurements of the two 2D-SWE systems were compared. LS values measured using the two 2D-SWE systems and TE were correlated using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Thereafter, Bland-Altman limits of agreement and intraclass correlation coefficients (ICCs) were used to analyze the intersystem reproducibility of LS measurements. RESULTS: The two 2D-SWE systems showed similar technical success rates (98.9% for both) and reliability of LS measurements (92.3% for the LOGIQ E9, 91.2% for the LOGIQ S8; P=0.185). Despite the excellent correlation (ICC=0.92), the mean LS measurements obtained by the two 2D-SWE systems were significantly different (LOGIQ E9, 6.57±2.33 kPa; LOGIQ S8, 6.90±6.64 kPa; P=0.018). CONCLUSION: Significant intersystem variability was observed in the LS measurements made using the two 2D-SWE systems. Therefore, even 2D-SWE systems from the same manufacturer should not be used interchangeably in longitudinal follow-up.


Subject(s)
Humans , Elasticity Imaging Techniques , Follow-Up Studies , Liver Cirrhosis , Liver Diseases , Liver , Reproducibility of Results , Retrospective Studies , Ultrasonography
20.
Korean Journal of Radiology ; : 1597-1615, 2019.
Article in English | WPRIM | ID: wpr-786371

ABSTRACT

Magnetic resonance imaging (MRI) plays an important role in abdominal imaging. The high contrast resolution offered by MRI provides better lesion detection and its capacity to provide multiparametric images facilitates lesion characterization more effectively than computed tomography. However, the relatively long acquisition time of MRI often detrimentally affects the image quality and limits its accessibility. Recent developments have addressed these drawbacks. Specifically, multiphasic acquisition of contrast-enhanced MRI, free-breathing dynamic MRI using compressed sensing technique, simultaneous multi-slice acquisition for diffusion-weighted imaging, and breath-hold three-dimensional magnetic resonance cholangiopancreatography are recent notable advances in this field. This review explores the aforementioned state-of-the-art techniques by focusing on their clinical applications and potential benefits, as well as their likely future direction.


Subject(s)
Cholangiopancreatography, Magnetic Resonance , Hand Strength , Magnetic Resonance Imaging